+86 18068001229 Transformers e Fa'asusu i le Suau'u ma le Ituaiga Matutu: O se Taiala Fa'atusatusa Atoatoa
I. Eseesega Autū
1. Fuafuaga & Puipuiga
Fa'amafanafanaga: Fa'apala'au epoxy resin pe fa'amafanafanaga mautu e le'i afifiina (e pei o le pepa Nomex).
Fausaga: O le fatu/viliina vaaia ma bushings silicone rubber.
Mea e taofia ai le vevela: Suāuu minerale po'o le suāuu ester fa'apitoa; fa'asusu atoa i totonu o se tane.
Fausaga: Tane ua fa'amaufa'ailogaina i ni fa'amau porcelain.
2. Malosiaga & Vaevaega o le Voltage

II. Fa'atusatusaga o le Fa'atinoga ma le Tau
1. Malosiaga e Malulu ma Soona ai
Lelei o le Fa'amālūlūina:
Ituaiga-Matūtū: Fa'amālūlūina fa'alenatura/fa'amalosia le ea (fa'atapula'aina le lelei).
Fa'asusu i le Suau'u: Fa'asalalauina o le suau'u (sili atu mo avega mamafa faifai pea).
Onosa'i i le Soona Tele:
Ituaiga-Mago: ≤1.5x le gafatia fa'atulagaina (taimi pu'upu'u).
Fa'asusu i le suāu'u: 30% so'ona fa'atumu mo le 1 itula.
2. Tau ma le Tausiga

III. Tulaga o Talosaga
1. Fa'aaogāga Fa'amalosia mo le Ituaiga Mago
Saogalemu i le Afi: Falema'i, auala i lalo o le eleele, fale maualuluga (epoxy e tete'e atu i le afi).
Tapula'a o le Avanoa: Potu i lalo, nofoaga laiti e fa'aaogaina ai le eletise (20% la'ititi ifo).
Sone e Ma'ale'ale i le Siosiomaga: O le mamanu e leai se suāuu e tausisia le RoHS.
2. Tulaga e Sili ona Manaomia i le Fa'asusuina i le Suau'u
Mana'oga Maualuga mo le Malosiaga: La'au Fa'avevela, paka fa'apisinisi (≥10MVA).
Siosiomaga Susū: Nofoaga i le talafatai, maina (e tete'e le suāuu i le susu).
Tau Matuā Faigata: Fa'atinoga mautu i le -40°C i le 45°C.
IV. Fa'asologa o Galuega Filifilia
Fa'amatala Mana'oga:Ituaiga avega (fa'aauau/te'i/felagolagoma'i), siosiomaga (sūsū/avanoa).
Fuafua le Malosiaga:S = Malosiaga o le Avega (kW) / Fa'asologa o le Malosiaga.
Vaega o le Fa'afetaui:
Saogalemu i le afi → Ituaiga-Mago (faasologa o le SCB)
Malosiaga maualuga/voltage → Fa'asusu i le suāuu (fa'asologa S13-M)
Tau-Aogā:Umi → Ituaiga-Matū (TCO maualalo); pu'upu'u → Fa'asusu i le Suau'u (CAPEX maualalo).
V. Aga Masani ma Fouga Fou
Ituaiga-Mago:
Mata'ituina Atamai: Sensors e fa'aogaina le IoT (e pei o le Siemens CoolBlue).
Voltage Maualuga: Faʻataʻitaʻiga faʻataʻitaʻi o le 66kV mo faʻatoʻaga matagi i fafo.
Fa'asusu i le Suau'u:
Fa'aleleia Atina'e: β-suau'u (tulaga afi ≥300°C) e sui ai le suau'u minerale.
Fuafuaga Fa'apu'upu'u: Tanka fa'amaufa'ailoga (15% la'ititi ifo le tulaga).
Faaiuga
E tutusa lava le fa'aaogaina o transformers e fa'asusu i le suāuu ma le ituaiga mago o ni fofo fa'aopoopo. Faatasi ai ma tulafono faatonutonu fa'amalosia (e pei o le EU Tier 3), e pulea e ituaiga mago vaega fa'apisinisi, ae o lo'o tumau pea le taua o le fa'asusu i le suāuu mo atina'e o le malosiaga. Mo se filifiliga sili ona lelei, paleni fa'amatalaga fa'apitoa ma tau o le olaga atoa.