Leave Your Message

Transformer Fa'apipi'i i le Pole Vaega Tasi—25 kVA

Fua Fa'atatau o le Voltage Autu: 19920V
Fua Fa'atatau o le Voltage Lona Lua: 120/240V
O LE TAIMI O LE TAP HV: 18924-20916V
ITUAIGA FESOOOTA'IGA: II0
ITUAIGA: Masani
SA: 150/30kV
Tulaga Faatonuina: IEEE C57.12.20, ANSI C57.12
Talosaga: Tufaina atu

    Fa'amatalaga o le Oloa

    E sili ona lelei le JZP i le gaosiga o transformers ANSI/IEEE/UL, ma faʻaalia ai le tomai faʻapitoa ma le agavaa i maketi i Matu ma Amerika i Saute. Latou te ofoina atu transformers e 25 kVA e tasi le vaega e faʻapipiʻi i le pou, lea e mafai ona mamanuina, gaosia, ma faʻapitoa e ausia ai tulaga faʻavaomalo eseese. O le tautinoga a le JZP i le tulaga lelei e avea ai i latou ma paʻaga faʻatuatuaina mo manaʻoga uma o transformers i Amerika ma tua atu.
    Transformer Fa'apipi'i i le Pole Vaega Tasi—25 kVA0
    25kVA 19.92kV Transformer Vaega Tasi
    O le DL-25/19.92/0.24(0.12), o se transformer e fa'apipi'i i le pou e tasi le vaega fa'apitoa
    O le transformer e fa'apipi'i i le pou e 25 kVA e fa'aaogaina ai mea e fa'apipi'i ai le alumini e sili ona lelei mo ona vaega maualuga ma maualalo-voltage, e fa'amautinoa ai le fa'atinoga sili atu ma le fa'atuatuaina. Fa'atasi ai ma le taua o le impedance e 2%, o lo'o i ai se vaega Vector o le Ii0 ma le polarity e Subtractive, e fa'aleleia atili ai lona lelei.
    O le voltage maualuga o le transformer faatasi ai ma tulaga eseese e lima o le faatonutonuina o le voltage, e maua ai le tele o fetuutuunaiga, ae o le vaega faatonutonu o le voltage o le 19.92kV±2×2.5% e mautinoa ai le mautu e tusa lava pe o taimi e fesuisuia'i ai.
    25kVA 19
    25kVA 7.2(12.47)kV/4.8(8.32)kV Transformer Vaega Tasi
    O le transformer e 25 kVA e fa'apipi'i i le pou e tasi le vaega e mitamita i se mamanu maualuga e lua. O lenei mea e mafai ai ona filifili lelei le maualuga o le voltage mai le 7.2kV po'o le 4.8 kV, e fetaui lelei ma mana'oga eseese o masini avega, ma ofoina atu ai le tele o mea e mafai ona fa'aogaina.
    O le transformer e aofia ai se faiga fa'amālūlū lelei a le ONAN, e fa'aopoopo i ai le suāuu minerale e leai se PCB 45#, e fa'amautinoa ai le saogalemu ma le tiutetauave i le siosiomaga.
    I le fa'aaogaina o le Ii6 vector group fa'atuatuaina ma le additive polarity, o le transformer o lo'o tu i luga o le fa'atinoga ma le fa'atuatuaina. O mea fa'aopoopo autu e aofia ai le 1 high voltage bushing, 3 low voltage bushings, 1 dual voltage switch, 1 pressure relief, 1 H2 terminal, 2 copper strips, 3 tank grounds, 2 support lugs, 2 lift lugs, ma le 6 cover clamps, e fa'amaonia ai lona mamanu fa'alelei ma le aoga.
    25kVA 7
    25kVA 17.32kV Transformer Vaega Tasi
    O lenei transformer e iai le voltage muamua e 17.32 kV ma le voltage lona lua e 230V, ua mamanuina ma le fa'aeteete ina ia fa'amalieina mana'oga fa'apitoa a le tagata fa'atau.
    Faatasi ai ma le uʻamea kopa i lona totonugalemu, o lenei transformer e mautinoa ai le sili atu ona lelei o le faatinoga ma le faatuatuaina. O loʻo faʻagaoioia i le televave o le 50 Hz ma faʻaalia ai se vaega Vector o le Ii0 faʻatasi ai ma le polarity faʻaopoopo, e mautinoa ai le tuʻufaʻatasia lelei i totonu o faiga eletise eseese.
    O le transformer ma le vaega fa'atonutonu o le 17.32kV±2×2.5%, e mafai ai ona sa'o ma mautu le voltage output e tusa lava pe eseese tulaga o avega.
    25kVA 17

    Fesili Nei!

    Mo ni fesili e uiga i a matou oloa po'o le lisi o tau, fa'amolemole tu'u mai lau imeli ma o le a matou fa'afeso'ota'i oe i totonu o le 24 itula.

    Leave Your Message