Fofo mo Suiga o le Malosiaga Fa'apitoa≤2500 kVA
Fa'asologa o oloa
| Ituaiga | Malosiaga | Tulaga o le Voltage | Fa'amālūlūina | Talosaga |
| Fa'aliliuga Fa'asalalau | 1,600 kVA | 11 kV / 400 V | TALAVOU | Nofoaga/fale gaosi oloa |
| Suiga o le Malosiaga | 500 MVA | 220 kV / 33 kV | OFAF | Nofoaga tutotonu o faasalalauga faaitulagi |
| Suiga Fa'aliliu UHVDC | ±400 kV / 500 MVA | ±800 kV HVDC | Suau'u fa'amalosia | Feso'ota'iga fa'avaomalo |
| Fa'aliliuga Fa'asa'o | 20 MVA | 33 kV / 1.8 kV × 6-pulse | Ituaiga mago, fa'amālūlūina i le ea | Elektrisi alumini |







fa'amatalaga o oloa
1. Malosiaga Fa'atulagaina (MVA/kVA)
Fa'amatalaga: O le malosiaga faifai pea aupito maualuga e mafai ona tu'uina atu e le transformer.
Lautele masani:
Mea Fa'aliliuina o le Fa'asalalauina: ≤2,500 kVA (e pei o le fa'asalalauga o le eletise i fale po'o fale gaosi oloa).
Masini Fa'aliliu Malosiaga: E faitau afe kVA i le tele o GVA (e pei o nofoaga fa'asalalau eletise).
Transformers Ultra-Maualuga le Voltage (UHV): Mo feso'ota'iga o upega po'o fa'aoga i fale gaosi oloa, e o'o atu i le ±800 kV HVDC converter transformers.
;2. Fuainumera o le Voltage
Volta Fa'aulufale/Fa'aulufale:
Voltage Maualuga (HV): E masani lava 33 kV i le ±1,100 kV (e pei o feso'ota'iga fa'asalalau).
Voltage Feololo (MV): Masani 11 kV, 22 kV, 33 kV.
Voltage Maualalo (LV): E masani lava 400 V pe 6.6 kV (tufatufa atu i tagata fa'aoga).
Talosaga Faapitoa:
Masini Fa'asa'o: Mo galuega tau u'amea/kemikolo, voltage e o'o atu i le 30 kV+.
Fa'aliliuga o le Malosiaga o Auala Nofoaafi: Ua fa'afetaui mo le malosiaga o le lokomotipi, mo se fa'ata'ita'iga, 27.5 kV po'o le 1×25 kV.
;
3. Taimi e masani ai
Masani: 50 Hz (Saina/Europa) po'o le 60 Hz (Amerika i Matu).
Fa'asalalauga Fa'apitoa: 400 Hz mo fa'aoga i vaalele/va'a.
;4. Faiga Fa'amālūlū
Fa'asusu i le Suau'u:
ONAN (Suāuu Faanatura Ea Faanatura): Fa'amālūlūina fa'anatura e ala i le fa'avevela o le convection.
ONAF (Suāuu Fa'alenatura e Fa'amalosia ai le Ea): Fa'amalosia le fa'amālūlūina o le ea mo le sili atu ona lelei.
Ituaiga Mago: E fa'amālūlūina i le ea, talafeagai mo totonu o fale/nofoaga e ma'ale'ale i afi (e pei o nofoaga autu o fa'amaumauga).
Fa'aputuga Kasa (GIS): Fa'aputuga kasa SF6, mamanu la'ititi mo nofoaga eletise tetele.
;5. Ituaiga o le Fa'amama
Fa'asusu i le Suāuu: Suāuu minerale po'o suāuu e fa'avae i le ester (e le afaina ai le siosiomaga).
Ituaiga-Māgogo: Fa'a'ofuofu epoxy resin po'o le pepa Nomex (te'ena mai le afi/pā).
Fa'amālūlūina i le Kasa: SF6 po'o kasa fefiloi (nofoaga eletise laiti e maualuga le voltage).
;6. Lelei
Taua Masani:
Fesuia'iga Fa'asalalau: ≥98% (maualalo le leai o se avega ma le leiloa o avega).
Masini Fa'aliliu Malosiaga: ≥99% (o fa'ata'ita'iga o le voltage maualuga tele e sili atu le lelei).
Tulaga Faatonuina: Usitaia le IEC 61620 po'o le IEEE C57.12 (e pei o mana'oga o le EU Ecodesign).
;7. Vaega Feso'ota'i
Eseesega o le Vaega: Ua fa'ailoa mai o le Dyn11, Yd11, e fa'ailoa mai ai sootaga o le vaega i le va o windings e pulea ai harmonics ma tafega pupuu.
;8. Voltage Impedance
Fa'amatalaga: Pasene o le pa'ū o le voltage i le taimi o su'ega o le feso'ota'iga pu'upu'u, e atagia ai le gafatia e tete'e atu ai i le feso'ota'iga pu'upu'u.
Taua Masani: 4–10% (transformers eletise), ≤4% (transformers tufatufaina).
;9. Si'itia o le Vevela
Tapula'a: O transformers e fa'asusu i le suāuu e masani ona fa'atagaina le si'itia o le vevela e ≤55 K (sili atu le suāuu i le 40°C le si'osi'omaga).
Fetuunaiga i le Siosiomaga: E manaʻomia e nofoaga o toafa le faʻaitiitia o le mamafa (deration) maualuga.
;10. Fua Fa'atatau o le Puipuiga
Fa'ailoga IP:
IP23: Puipuiga mai le pefu, tete'e atu i le vai.
IP66/IP68: Fa'amaufa'ailoga atoatoa mai le pefu/vai (fa'aoga i le sami/fa'avaomalo).
Siosiomaga Faapitoa: Tete'e atu i le ele mai le suāsusu masima mo le fa'aaogaina i le talafatai/i lalo o le sami.
11. Ituaiga Fa'apitoa
Fa'aliliuga Fa'asa'o: Fuafuaga e tele-pulse (e pei o le 12/24-pulse) e fa'aitiitia ai le harmonics.
Transformers e Suia le Tap: O tap changers e fa'aaogaina le uta (OLTC) mo le fa'atonutonuina o le voltage.
Fa'aliliuga Fa'apitoa:
Mea Fa'aliliu i le Ogaumu Eletise: Fuafuaina mo le so'ona fa'atumuina i se taimi pu'upu'u (e pei o le fa'ama'a'aina o u'amea).
Zigzag Transformers: Faiga fa'avae e le fa'avae mo le taofiofia o le harmonic.
Ituaiga Malosiaga Tulaga o le Voltage Fa'amālūlūina Talosaga
Fa'aliliuga Fa'asalalau 1,600 kVA 11 kV / 400 V ONAN Nofoaga/fale gaosi oloa
Transformer Malosiaga 500 MVA 220 kV / 33 kV OFAF Nofoaga Autu mo Felauaiga Fa'aitulagi
UHVDC Converter Transformer ±400 kV / 500 MVA ±800 kV HVDC Suau'u fa'amalosia o le Intercontinental grids
Transformer Fa'asa'o 20 MVA 33 kV / 1.8 kV × 6-pulse Electrolysis alumini ituaiga mago, malulu i le ea



Aiseā e filifili ai i matou
O JIEZOU POWER, o se tagata mamanu fa'apolofesa, gaosi oloa ma fa'apipi'i fofo mo le fa'aogaina o le eletise i le lalolagi atoa, na fa'avaeina i le 1989, ma e 200,000 mita faatafafa lona lautele.
O le JIEZOU POWER, e pulea faapitoa galuega faatino o le upega eletise, 500KV EPC, fale eletise vai 230KV, fale eletise e 115KV, ma isi.
E mafai e le fale gaosi oloa o JIEZOU POWER ona gaosia ni transformer tufatufaina ituaiga suāuu ma ituaiga mago, transformer eletise e oʻo atu i le 500KV 480MVA, GIS, switchgear, substation, e faʻavae i luga o le tulaga faʻatonuina o le ANSI/IEEE/DOE2016/CSA/IEC60076.
Ua fa'asolosolo ona maua e le JIEZOU POWER le tusipasi ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Se'ia o'o i le tausaga 2023, o lo'o salalau atu kamupani lala ma falegaosimea i le lalolagi atoa i le Iunaite Setete, Kanata, Dubai, Dominican Republic, Filipaina, o lo'o iai falegaosimea ma kamupani lala Saina i le a'ai o BengBu, FengYang, HaiAn, TaiZhou, SuZhou, ShenYang, ma FoShan.
I le vaavaai atu i le lumanai, o le vaaiga a le JIEZOU POWER o le avea lea ma kamupani e sili ona faatuatuaina e tuʻuina atu fofo mo le faiga o le eletise, foia luʻitau sili ona faanatinati i le lalolagi mo le puleaina o le eletise, faatelevaveina le suiga o le paneta i le malosiaga faafouina. Ina ia mafai e tagata uma ona maua se olaga e sili atu ona maualalo le kaponi ma susulu. Mo lenei faamoemoega, o le a matou faia le mea sili matou te mafaia e faia ai taumafaiga.



Fesili Nei!
Mo ni fesili e uiga i a matou oloa po'o le lisi o tau, fa'amolemole tu'u mai lau imeli ma o le a matou fa'afeso'ota'i oe i totonu o le 24 itula.